85
3-6-6 Registered character settings: RKC
Sets the input format of the “Registered characters” function used to switch characters by I/O input.
⿎
Setting request data / response data for readout
Start
code
RKC
Sub
command
[I/O input format]
1-byte
(Check
sum)
End code
Sub command is “S” for the setting request data and “A” for the response data for readout.
⿎
Readout request data
Start
code
RKC
R
(Check sum)
End code
⿎
Data description
Name
Data length [byte]
Data contents
Remarks
I/O input format
1
“1”: 4-bit x 4
“2”: 8-bit x 2
It is the assignation method of the data number
for I/O terminal.
Total data length
1
The data length is fixed.
⿎
Example of command settings
Condition:
I/O input format = 1
• Setting
Transmission data
[STX]
RKC
S
1
[CR]
• Readout
Transmission data
[STX]
RKC
R
[CR]
Response data
[STX]
RKC
A
1
[CR]
ンㄆㄇㄆㄓㄆㄏㄆ
• Registered characters (via I/O) cannot be set together with the following functions in one file.
• Characters specified by SIN command
• External offset function with “Using SEO command”
• On-the-fly marking at regular intervals
• On-the-fly marking with multiple triggers
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...