89
3-7-2 Bar code/2D code characters (by ASCII and Shift-JIS code): BRS
Sets the characters to encode of the bar code/2D code objects. Characters including control codes (specified with 2-byte
alternative codes), alpha-numeric, functional characters, and Japanese characters are available.
⿎
Setting request data / response data for readout
Start
code
BRS
Sub
command
[Object No.] [String No.] [Code data]
Max. 62-byte or Max. 63-byte
(Check
sum)
End code
Sub command is “S” for the setting request data and “A” for the response data for readout.
⿎
Readout request data
Start
code
BRS
R
[Object No.] [String No.]
2-byte or
3-byte (2D side of composite code)
(Check
sum)
End code
⿎
Data description
Name
(> Name in LP-400/V)
Data length
[byte]
Data contents
Remarks
Object No.
(> Bar code No.)
1
“0”–“7”: Object No. 1100 to 1107
String No.
1
or
2
For bar code/ 1D side of composite
code:
“1”–“2”
• The string No. is applied to the linefeed
of the human readable character. The
linefeed is not included in the code data.
• If the code data length is more than 60-
byte, set the character in the several
string No. They are connected together
in numerical order without linefeed to
create the code data.
• For EAN/UPC/JAN or 1D side of GS1
DataBar Limited/Stacked, set “1” always.
• Only for 2D side of the composite code,
set this item with 2-byte length.
For 2D code:
“1”–“9”
For 2D side of composite code:
“01”–“09”
Code data
Min. 0
Max. 60
Input Method: ASCII code or Shift
JIS code (can be mixed)
• Use the ASCII code to specify functional
characters.
• Use the Shift JIS code to specify two-
byte characters (double byte characters).
• For the characters that can be specified
in ASCII code, you can use both ASCII
code and Shift-JIS code.
• Specify 0-byte for data length to delete
characters.
• For response data for readout, all
characters except the functional
characters are readout in 2-byte
characters (Shift-JIS code) regardless
the settings.
Total data length
Max. 62
or
Max. 63
Variable length.
• For bar code/2D code/1D side of composite code: Max. 62-byte
• For 2D side of composite code: Max. 63-byte
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...