124
⿎
Example of command settings
Condition:
Moving direction = 2, Line speed control = 1, Trigger mode = 0
• Setting
Transmission data
[STX]
TRG S
210
[CR]
• Readout
Transmission data
[STX]
TRG R
[CR]
Response data
[STX]
TRG A
210
[CR]
3-11-2 Encoder resolution: ENC
Supported model: LP-RC series / LP-RF series / LP-RV series
Sets the encoder resolution value used for the on-the-fly marking. This setting is applied to all marking files.
⿎
Setting request data / response data for readout
Start
code
ENC
Sub
command
[Encoder resolution]
6-byte
(Check
sum)
End code
Sub command is “S” for the setting request data and “A” for the response data for readout.
⿎
Readout request data
Start
code
ENC
R
(Check sum)
End code
⿎
Data description
Name
Data length
[byte]
Data contents
Remarks
Encoder resolution
6
“005.00”–“600.00” [pulses/mm]
Only when line speed control is set to
“encoder input”, set this value.
Total data length
6
Fixed length.
ンㄆㄇㄆㄓㄆㄏㄆ
• The setting changed by this command is saved in the laser marker without overwriting to the file.
⿎
Example of command settings
Condition:
Encoder resolution = 120.5
• Setting
Transmission data
[STX]
ENC S
120.50
[CR]
• Readout
Transmission data
[STX]
ENC R
[CR]
Response data
[STX]
ENC A
120.50
[CR]
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...