![background image](http://html1.mh-extra.com/html/panasonic/lp-gs-series/lp-gs-series_serial-communication-command-manual_3637167148.webp)
148
Troubles
Causes
Measures
The sending
command is not
accepted and
negative response is
returned.
The requested operation can
be controlled only by I/O with
the current system settings.
To control the following commands with the serial
communication, specify the control method to the
communication command in Laser Marker NAVI smart system
settings and restart the laser marker.
• Laser pumping (LSR)
• Shutter open/close (SHT)
• Guide Laser (GID) (LP-GS051(-L) type, LP-RC350S, LP-RF
and LP-RV series only)
The following commands are available only when the shutter
open/close control method is set to communication command.
• Laser radiation for measurement (SPT)
“Reception mode ON”
is not set for command
reception permission (MKM
command).
Except the following commands *, the laser marker cannot
accept the command unless it is in the “reception mode ON”
status. For command transmission, set “reception mode ON” by
MKM command.
• File selection by number (FNO)
• File selection by name (FNN)
• Shutter open/close (SHT)
• Command reception permission (MKM)
• Laser pumping (LSR)
• Counter reset (CTR)
• Status checking (STS)
• Marking trigger (MRK)
• Character entry per trigger (SIN)
• Marking position and laser power adjustment per trigger (SEO)
• Runtime data (RTD)
Alarm or Warning occurred.
All commands except the following commands * cannot be
accepted while alarm or error is active.
When alarm occurred:
• Status checking (STS)
• Runtime data (RTD)
• Alarm reset (ARS)
• Error code (ENO)
When warning occurred:
• Status checking (STS)
• Runtime data (RTD)
• Alarm reset (ARS)
• Error code (ENO)
• Shutter open/close (SHT) (Only closing and readout request)
• Command reception permission (MKM) (readout only)
Two or more command data
are transmitted at the same
time.
After sending the command, confirm the response data from the
laser marker. Do not send the next command before receiving
the response.
Command mode (LP-400/V
compatibility setting) is wrong.
• If you want to use the same command format with the
former models of LP-400/LP-V series, enable “LP-400/V
compatibility” in system settings of Laser Marker NAVI smart.
• If you want to use the standard command format, switch the
mode by RSM command or disable “LP-400/V compatibility”
in system settings of Laser Marker NAVI smart.
* These commands are applicable with the standard command mode. For the LP-400/V compatible mode, refer to the “Serial
Communication Command Guide: LP-400/V compatible mode”.
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...