3-8-2 Graphic object settings (VEC format file) : CDC
Sets the parameters such as the position and size of the graphic objects (VEC format file).
ンㄆㄇㄆㄓㄆㄏㄆ
• This command cannot be used for other than VEC format graphic, such as DXF, BMP, JPEG or HPGL etc.
• The VEC format is a graphic format converted for the laser marker use.
• If the object type set in the specified object number is not the graphic (VEC), the laser marker returns the negative
response.
⿎
Setting request data / response data for readout
Start
code
CDC
Sub
command
[Object No.] [System reserved value]
[X-scaling] [Y-scaling] [X-position] [Y-position]
[Rotation angle] [Laser power correction]
[Scan speed correction]
[Pulse cycle correction]
LP-GS/LP-RC: 48-byte
LP-RF/LP-RV: 51-byte
(Check
sum)
End code
Sub command is “S” for the setting request data and “A” for the response data for readout.
⿎
Readout request data
Start
code
CDC
R
[Object No.]
2-byte
(Check
sum)
End code
⿎
Data description
Name
(> Name in LP-400/V)
Data length
[byte]
Data contents
Remarks
Object No.
(> Logo No.)
2
“00”–“15”: Object No. 1200 to 1215
System reserved
value
1
“0”–“9”, “A”–“F”
This value does not affect the settings
anymore.
X-scaling
8
“0010.000”–“1000.000” [%]
The correction ratio is calculated using
the size of the saved graphic data as
100%.
Y-scaling
8
X-position
8
“-999.999”–“+999.999” [mm]
Specifies the origin coordinate of the
graphic.
The graphic origin is the position
specified when converting the graphic
data into a VEC file.
Y-position
8
Rotation angle
7
“-180.00”–“+180.00” [°]
The rotation center is the origin of the
graphic.
Laser power
correction
3
“000”–“999” [%]
The correction ratio is calculated using
the value set at the laser settings as
100%.
Scan speed
correction
3
“001”–“999” [%]
Pulse cycle
correction *
(3)
“001”–“999” [%]
Total data length
48
or
51
The data length is fixed.
• LP-GS/LP-RC series: 48-byte
• LP-RF/LP-RV series: 51-byte
* Only for LP-RF series and LP-RV series.
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...