121
⿎
Setting request data / response data for readout: when mark OFF setting
Start
code
SRA
Sub
command
[Adjustment No.] [Adjustment object]
[Target row] [Target column]
( [Target row] [Target column] …)
At setting: 3 + 6n-byte
At readout: 9-byte
(Check
sum)
End code
Sub command is “S” for the setting request data and “A” for the response data for readout.
⿎
Data description
Name
Data length
[byte]
Data contents
Remarks
Adjustment No.
2
“00”–“99”
If the several pairs of the target row and target
column are specified, each setting is set in the
subsequent No. from the specified No.
Adjustment object
1
“2”: Mark OFF
Target row
3
“001”–“400”
• When the mark OFF setting is applied to only
one data, do not send the further data.
• Specify both row and column. It is not possible
to omit one side of them.
Target column
3
…
…
• When the mark OFF is set to two or more data,
set the next row and column in series. These
settings are set in the subsequent adjustment
No.
• Max. 100 pairs of row and column can be set.
Target row
(3)
Target column
(3)
Total data length
Min. 9
Max. 603
Variable length with 3 + 6n-byte
n = number of the setting pairs of row and column (n
≦
100)
• When setting only one pair of row and column: 9-byte
• When setting 100 pairs of row and column: Max. 603-byte
• Response data for readout: 9-byte
⿎
Example of command settings
Condition:
Adjustment No. = 01, Adjustment object = 2,
Target row = 4, Target column = 4, Target row = 8, Target column = 8
• Setting
Transmission data
[STX]
SRA
S
012004004008008
[CR]
• Readout
Transmission data
[STX]
SRA
R
01
[CR]
Response data
[STX]
SRA
A
012004004
[CR]
ンㄆㄇㄆㄓㄆㄏㄆ
• With LP-400/V compatible command mode, the Mark OFF can not be set to the unit of whole rows and columns.
• With LP-400/V compatible command mode, the setting cannot be readout if the Mark OFF is set to other than the single
step.
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......