152
ERROR
CODE
Description
Measures *1
E402
E403
E501
LASER STOP IN of the I/O terminal block was
released.
• Connect the LASER STOP IN terminals of the
I/O terminal block.
• Check the status of the safety equipment
connected to the LASER STOP IN terminals.
• Confirm operation logic of connection device.
• Connect the internal or external power supply
to IN COM.1 and OUT COM.1 in the I/O
terminal respectively.
E404
E502
The stop laser button of the Laser Marker NAVI
smart was pressed.
Press the stop laser button of Laser Marker NAVI
smart to release.
REMOTE INTERLOCK IN is open.
• Connect REMOTE INTERLOCK IN of the I/O
terminal block.
• Check the status of the safety equipment
connected to REMOTE INTERLOCK IN
terminal.
• Confirm operation logic of connection device.
• Connect the internal or external power supply
to IN COM.1 and OUT COM.1 in the I/O
terminal respectively.
E410
Laser pumping was stopped during the marking
process.
• Start marking after laser pumping has
completed.
• Check the procedures and operation logic of
laser pumping and trigger input control.
• Check wiring of I/O or communication port to
the external control devices.
• Check the switch or the sensor connected to
TRIGGER IN of I/O terminal operates properly
without chattering.
E411
E500
The marking trigger signal or “Start marking”
button was entered in the “laser pumping OFF”
status.
E450 - E453
• The date and time of the system clock may be
out of synchronization.
• The system clock battery power in the
controller died.
• Abnormality has occurred on the system clock
in the controller.
• Check the system clock time and set it again.
• Replace the internal battery by following the
“Replacement of Internal Controller Battery” in
the Setup/Maintenance Guide.
• While laser marker power is on, you can use
it after setting the system clock on the system
settings screen. When the power is off, set the
system clock again.
E460 *2
Temperature error in laser oscillator.
• Check if the ambient temperature of the
laser marker is not exceeding the range of its
specification.
• Make sure air-cooling fan operates.
• Remove the dust and contamination in the
air intake and exhaust port, and clean the air-
cooling part such as fan and filter.
• When not recovered, contact our sales office
or representatives.
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...