3-13 Maintenance Commands
3-13-1 Laser radiation for measurement: SPT
Controls “laser radiation for measurement” used to measure laser output by a commercially available power meter.
⿎
Setting request data
Start
code
SPT
S
[Radiation on/off]
1-byte
(Check
sum)
End code
⿎
Data description
Name
Data length
[byte]
Data contents
Remarks
Radiation on/off
1
“0” or “2”: Stop radiation
“1”: Start radiation
• The internal shutter is automatically
opened and closed at the time of
start and stop of radiation.
• Though with LP-400/V series “2”
was “Stop radiation temporarily”,
with this product “2” represents just
“Stop radiation”.
Total data length
1
The data length is fixed.
ンㄆㄇㄆㄓㄆㄏㄆ
• To start the laser radiation for measurement with this command, set the shutter control method to “communication
commands” by Laser Marker NAVI smart.
• You can start the laser radiation for measurement only when the laser pumping is completed and the shutter is closed.
• The laser radiation is automatically stopped after about one minute even if the stop request command was not sent. At
this time the internal shutter is automatically closed.
• The laser settings (laser power / pulse cycle or laser frequency / pulse duration) set in the selected file are applied to
the laser radiation for measurement. Even if you have set the different settings for the laser radiation for measurement
by using Laser Marker NAVI smart, the radiation settings are overwritten with the laser settings in the selected file when
you execute the radiation by this command.
• If you correct the laser power in the system settings, this correction is always applied to the laser radiation for
measurement when you execute the radiation by this command.
• The laser for measurement is radiated at the center of marking field. The system offset of X-/Y-position in the system
settings are not applied to this function.
• With LP-RC series, it takes around 300ms to max. 4 seconds to start laser radiation after sending the radiation request.
• With LP-RC series for the first laser radiation after the laser pumping on, warning E640 may occur in case the laser
pumping has been off for more than several days. In this case, send the shutter close request or input alarm reset to
recover from the warning status, and then retry lasing operation.
• Do not execute any other operation including the shutter opening/closing and sending MKM command during the laser
radiation for measurement.
• If you want to radiate the laser to the arbitrary points, use “Point radiation” function instead of this function.
⿎
Example of command settings
Condition:
Radiation on/off = 1
• Setting
Transmission data
[STX]
SPT
S
1
[CR]
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...