67
3-4-3 Overwrite file: FOR
Overwrites the current file onto the laser marker.
⿎
Setting request data
Start
code
FOR
S
(Check sum)
End code
⿎
Example of command settings
• Setting
Transmission data
[STX]
FOR
S
[CR]
ンㄆㄇㄆㄓㄆㄏㄆ
• By this command, in addition to the editing file contents, the settings of the global functional characters such as global
counter, date and lot, and reference list characters for all files are saved to the laser marker.
• When the setting is changed by the following commands, the modified data is saved in the laser marker without
overwriting operation.
• Current counter value of counter settings (CNT)
• Counter reset (CTR)
• Motion settings (TRG)
• Encoder resolution (ENC)
• System clock (YMD)
3-4-4 Save file to different No.: FRG
Saves the current file to the specified file number in the laser marker.
⿎
Setting request data
Start
code
FRG
S
[File number]
4-byte
(Check sum)
End code
⿎
Data description
Name
Data length
[byte]
Data contents
Remarks
File number
4
“0000”–“9999”
When you save files by this command, the active file
number is switched to the selected number.
Total data length
4
The data length is fixed.
⿎
Example of command settings
Condition:
File number = 1234
• Setting
Transmission data
[STX]
FRG
S
1234
[CR]
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...