Example of command settings
Condition:
When the linefeed is enabled
Object No. = 1, Positional offset target = 1, Relative X-position = 10, Relative Y-position = -5.5,
Character height = 3, Character width = 3, Character spacing = 3, Font No. = 2,
Laser power correction = 100, Scan speed correction = 200, Pulse cycle correction = 100,
Linefeed = 1, Linefeed spacing = 3.5
• Setting
Transmission data
[STX]
BRV
S
11+010.000-005.500003.000003.000003.000
21002001001003.500
[CR]
• Readout
Transmission data
[STX]
BRV
R
1
[CR]
Response data
[STX]
BRV
A
11+010.000-005.500003.000003.000003.000
21002001001003.500
[CR]
Condition:
When the linefeed is disabled
Object No. = 1, Positional offset target = 1, Relative X-position = 10, Relative Y-position = -5.5,
Character height = 3, Character width = 3, Character spacing = 3, Font No. = 2,
Laser power correction = 100, Scan speed correction = 200, Pulse cycle correction = 100,
Linefeed = 0
• Setting
Transmission data
[STX]
BRV
S
11+010.000-005.500003.000003.000003.000
2100200100
[CR]
• Readout
Transmission data
[STX]
BRV
R
1
[CR]
Response data
[STX]
BRV
A
11+010.000-005.500003.000003.000003.000
21002001000
[CR]
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...