126
3-11-4 Workpiece spacing: INT
Supported model: LP-RC series / LP-RF series / LP-RV series
Sets the distance between the workpieces for the on-the-fly marking at regular intervals for the selected marking file.
⿎
Setting request data / response data for readout
Start
code
INT
Sub
command
[Workpiece spacing]
6-byte
(Check
sum)
End code
Sub command is “S” for the setting request data and “A” for the response data for readout.
⿎
Readout request data
Start
code
INT
R
(Check sum)
End code
⿎
Data description
Name
Data length
[byte]
Data contents
Remarks
Workpiece spacing
6
“0000.0”–“4000.0” [mm]
Only when trigger mode is set to “Marking
at regular intervals”, set this value.
Total data length
6
Fixed length.
⿎
Example of command settings
Condition:
Workpiece spacing = 200
• Setting
Transmission data
[STX]
INT
S
0200.0
[CR]
• Readout
Transmission data
[STX]
INT
R
[CR]
Response data
[STX]
INT
A
0200.0
[CR]
ME-LP-GS-SR-COMP-3