3-6-5 Lot period/character: LTS
Sets the characters used with the “Lot” function to change characters depending on the date/time and counter values.
⿎
Setting request data / response data for readout
Start
code
LTS
Sub
command
[Lot No.] [Period No.] [Start period]
[End period] [Lot character]
Max. 33-byte
(Check
sum)
End code
Sub command is “S” for the setting request data and “A” for the response data for readout.
⿎
Readout request data
Start
code
LTS
R
[Lot No.] [Period No.]
3-byte
(Check
sum)
End code
⿎
Data description
Name
Data length
[byte]
Data contents
Remarks
Lot No.
1
“0”–“3”: Lot 0 to 3
“4”–“7”: Global lot 16 to 19
You cannot select the lot No.
without any settings by LTC
command or by Laser Marker
NAVI smart.
Period No.
2
Lot unit
Setting range
Year, Year (week-based)
“01”–“60”
Month
“01”–“12”
Date
“01”–“31”
Year and month
“01”–“60”
Month and date
“01”–“60”
Day of week
“01”–“07”
Hour
“01”–“24”
Week
“01”–“54”
Minute
“01”–“60”
Hour and minute
“01”–“60”
Counter
“01”–“60”
• It is the number that
separates periods to switch
lot characters.
• The setting range varies by
the lot unit.
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...