107
⿎
Example of command settings
Condition:
Object No. = 1, System reserved value = 0, X-scaling = 200, Y-scaling = 200,
X-position = 15, Y-position = -20, Rotation angle = 120,
Laser power correction = 50, Scan speed correction = 100
• Setting
Transmission data
[STX]
CDC S
0100200.0000200.000+015.000-020.000
+120.00050100
[CR]
• Readout
Transmission data
[STX]
CDC R
01
[CR]
Response data
[STX]
CDC A
0100200.0000200.000+015.000-020.000
+120.00050100
[CR]
ME-LP-GS-SR-COMP-3