97
6. When the code type is GS1 DataBar Stacked
When the code type is GS1 DataBar Stacked CC-A and specify its 1D side settings
Name
(> Name in LP-400/V)
Data length
[byte]
Data contents
Remarks
Object No.
(> Bar code No.)
1
“0”–“7”: Object No. 1100 to 1107
System reserved
value
(Area No.)
1
“0”–“9”, “A”–“F”
This value does not affect the settings
anymore.
Code type
2
“31”: GS1 DataBar Stacked
“41”: GS1 DataBar Stacked CC-A
For the composite codes, this setting is
applied to both 1D and 2D side.
Human readable text
1
“0”: OFF
“2”: ON
Invert
and
left/right guard
pattern width to
module width ratio
1
Setting
Invert
Left/right guard width
to module ratio
“0”
Not invert
1.0, 1.0
“1”
Invert
1.0, 1.0
“2”
Invert
2.0, 2.0
• Set “0” to mark a bar, “1” or “2” to
mark a space.
• When the inversion is enabled,
select the left/right guard pattern
width to module width ratio.
• The readout value is always “2”
when the inversion is enabled,
regardless the settings of left/right
guard pattern.
Lower barcode
height
7
Model
Setting range [mm]
LP-GS051(-L)
“000.050”–“055.000”
LP-GS052
“000.050”–“030.000”
LP-RC350S
“000.050”–“085.000”
LP-RF200P
LP-RV200P
“000.050”–“090.000”
In Laser Marker NAVI smart, this
setting is converted to the height ratio
of the lower side to module width and
displayed as “Lower barcode height to
module width ratio”.
Separator height to
module width ratio
4
“00.0”–“10.0”
Specifies the ratio of GS1 DataBar
Stacked separator to module width.
Module width
5
“0.050”–“1.000” [mm]
Specify a larger value than the line
width in the object group settings.
X-position
8
“-999.999”–“+999.999” [mm]
• It is the center coordinate of the
code.
• The rotation center is the center of
the code symbol.
Y-position
8
Rotation angle
7
“-180.00”–“+180.00” [°]
Laser power
correction
3
“000”–“999” [%]
• The correction ratio is calculated
using the value set at the laser
settings as 100%.
• At LP-400/V compatible command
mode, the same correction values
are applied to the separator.
Scan speed
correction
3
“001”–“999” [%]
Pulse cycle
correction *
(3)
“001”–“999” [%]
Total data length
47
or
50
The data length is fixed.
• LP-GS/LP-RC series: 47-byte
• LP-RF/LP-RV series: 50-byte
* Only for LP-RF series and LP-RV series.
ンㄆㄇㄆㄓㄆㄏㄆ
• With LP-400/V compatible command mode, “Code marking direction” cannot be set. To this item the setting by Laser
Marker NAVI smart or the initial value if it was not set, is applied.
• With LP-400/V compatible command mode, it is not possible to set the arbitrary value to “Left guard width to module
width ratio” and “Right guard width to module width ratio”.
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...