ンㄆㄇㄆㄓㄆㄏㄆ
• If the object type set in the specified object number is not the bar code/2D code, the laser marker returns the negative
response.
• Refer to “2-3-5 Character data input method” (P.37) for details on the character input method and character types with
input restrictions.
• Depending on the barcode/2D code type, acceptable characters may be restricted to either single-byte characters or
double-byte characters. In this case, the input characters are automatically converted to the accepted type.
• When the code data is set in the several string No., the characters in each string No. are connected together in
numerical order without linefeed to create the code data.
• When the code data is set in the several string No., the total input characters should be 299 digits or less.
• To input the control codes in the barcode/2D code data, refer to “Inputting control codes to bar code/2D code character
• For response data for readout, all characters except the functional characters are readout in 2-byte characters (Shift-JIS
code) regardless the settings.
• When the character strings set with the functional character are readout, the setting of the functional character starting
with % are read out. The characters to mark as the functional characters, such as the counter or date and time values,
are not read out.
• With LP-400/V compatible command mode, you cannot readout the character strings with more than 61-byte length.
• With LP-400/V compatible command mode, you cannot set and readout the strings for PDF417, iQR code, QR code for
Chinese characters (GB/T 18284), and CODE93.
• With LP-400/V compatible command mode, you cannot set and readout the strings for QR code with the mode setting
“Auto”.
⿎
Example of command settings
Condition:
Object No. = 0, String No. = 1, Code data (counter function and character “abcd”) = %06:C0abcd
• Setting
Transmission data
[STX]
BRS
S
01%06:C0abcd
[CR]
• Readout
Transmission data
[STX]
BRS
R
01
[CR]
Response data
[STX]
BRS
A
01%06:C0
abcd
[CR]
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...