64
⿎
Automatic response data with response permitted
The following response data transmit normal end or abnormal end at the end of the trigger processing (marking) with the
marking end verification response permitted.
Start
code
MST
A
[Status]
4-byte
(Check sum)
End code
⿎
Data description
Name
Data length
[byte]
Data contents
Remarks
Status
4
“0000”: Normal end
“E001”–“E999”: Error
code (abnormal end)
• It returns the error code occurred in case of an
abnormal end by an error during marking trigger
processing.
• When the warning that does not interrupt the
marking operation (E700 to E799) occurs, the
response data indicates “0000” as the normal end.
Total data length
4
The data length is fixed.
ンㄆㄇㄆㄓㄆㄏㄆ
• Refer to “Error Indication” (P.150) for error codes details.
• The automatic response data of the error code will not be transmitted in case of errors occurred when the marking
trigger processing is not in progress.
• When on-the-fly marking with multiple triggers or at regular intervals are set, the response data is transmitted at the
timing of each marking completion.
• When the marking interval is too short for transmission time of MST command, MST command is not available. In such
case, check the marking completion by I/O.
⿎
Example of command settings
Condition:
Response setting = 1
• Setting
Transmission data
[STX]
MST
S
1
[CR]
• Readout
Transmission data
[STX]
MST
R
[CR]
Response data
[STX]
MST
A
1
[CR]
Condition:
Status = 0000 (normal end)
• Response data with
response permitted
Response data
[STX]
MST
A
0000
[CR]
Condition:
When the alarm E400 occurred at the marking.
Status = E400
• Response data with
response permitted
Response data
[STX]
MST
A
E400
[CR]
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...