78
3-5-5 Character object settings (shortened): SPC
Sets only X-/Y-position and laser power correction in the character object settings.
ンㄆㄇㄆㄓㄆㄏㄆ
• You can use this command as a shortened command consisting only of X-/Y-positions and laser power correction of the
character object settings (STC) command.
• This command is applied to the character objects (reference list type).
⿎
Setting request data / response data for readout
Start
code
SPC
Sub
command
[Object No.] [X-position] [Y-position]
[Laser power correction]
21-byte
(Check
sum)
End code
Sub command is “S” for the setting request data and “A” for the response data for readout.
⿎
Readout request data
Start
code
SPC
R
[Object No.]
2-byte
(Check
sum)
End code
⿎
Data description
Name
(> Name in LP-400/V)
Data length
[byte]
Data contents
Remarks
Object No.
(> Character condition No.)
2
“01”–“60”: Object No. 1001 to
1060
X-position
8
“-999.999”–“+999.999” [mm]
Specifies the origin coordinate of
character strings.
Y-position
8
Laser power correction
3
“000”–“999” [%]
The correction ratio is calculated using
the value set at the laser settings as
100%.
Total data length
21
Fixed length.
⿎
Example of command settings
Condition:
Object No. = 01, X-position = 15, Y-position = -10, Laser power correction = 80
• Setting
Transmission data
[STX]
SPC
S
01+015.000-010.000080
[CR]
• Readout
Transmission data
[STX]
SPC
R
01
[CR]
Response data
[STX]
SPC
A
01+015.000-010.000080
[CR]
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...