63
3-3-8 Marking end verification: MST
Enables automatic response of marking result (e.g. normal end, and error occurrence, etc.) at the end of marking.
For the communication sequence of this command, refer to “Communication sequence when the marking end verification
(MST) command response is enabled” (P.29).
⿎
Setting request data / response data for readout
Start
code
MST
Sub
command
[Response setting]
1-byte
(Check sum)
End code
Sub command is “S” for the setting request data and “A” for the response data for readout.
⿎
Readout request data
Start
code
MST
R
(Check sum)
End code
⿎
Data description
Name
Data length
[byte]
Data contents
Remarks
Response setting
1
“0”: Response prohibited
“1”: Response permitted
Total data length
1
The data length is fixed.
ンㄆㄇㄆㄓㄆㄏㄆ
• Once you set the response settings of the marking end verification, they are valid during the remote mode.
• When the marking end verification is used, set the response permission before every shifting to the remote mode. This
command setting will be restored to the response prohibited state once you deactivate the remote mode.
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...