*43154*
BC-2500 SWITCH MODE UTILITY CHARGER, 8 SLOT
CHASSIS
FLOOR MOUNTING INSTALLATION INSTRUCTION
1
2
3
4
5
6
7
ITEM NO.
ITEM DESCRIPTION
QTY. / ASSY.
2
2
4
16
4
16
16
BRACKET, BASE
BRACKET, BRACE / EXTENSION
BRACKET, LEG
SCREW, #8-32 X .375, SELF TAPPING, PANHEAD
WASHER, #8, LOCK, STAR
SCREW, #10-32 X .250, HEX HEAD
NUT, #10-32, LOCKING
1
2
3
4
5
6
7
8 SLOT CHASSIS FLOOR MOUNTING PATTERN
WALL
2.750” MIN. MAINTAINS 2” CLEARANCE TO WALL
1
1.750”
15”
4X ø3/8”
STUD MAX.
Recommended Procedure
1. Remove charger supplied rack mounting or pallet
mounting brackets if present.
2. Using two people, place charger on its back side.
3. Attach item #3, leg brackets (4 per charger assembly)
as shown using supplied hardware, item # 4, #8
screws (4 per leg). Use one #8 washer, item #5 (on 1
screw per leg). Torque to 18 in-lbs.
4. Attach item #1, base bracket, to ends of legs as shown
using hardware items #6, #10 screw & #7 #10 lock nut
(2 each per leg). Torque to 22 in-lbs.
5. Attach item #2, brace bracket, in-between front and
back legs as shown using hardware items #6, #10
screw & #7 #10 lock nut (4 each per brace). Torque
to 22 in-lbs.
6. Using two people, place charger back upright on the
desired mounting surface. Use the “floor mounting
pattern provided at top & user supplied hardware,
torque appropriately.
Eagle Eye Power Solutions, LLC
●
4031 W Kiehnau Ave
,
Milwaukee
,
WI
53209
P:
1-877-805-3377
I
www.eepowersolutions.com