background image

Druck DPI 620

advanced modular calibrator

safety and quick reference guide - K0454

GE

Sensing & Inspection Technologies

A1.1

DPI 620: Channel 1 (CH1)

Measure (M) / Source (S) / Power (P)

a

±30 V (M)

b

0 to 12 V (S)

c

±2000 mV (M)

0 to 2000 mV (S)

Figure C1

Note: 

= See figure or 

table.

d

0 to 4000 

Ω

 (M/S)

e

0 to 50 kHz (M/S)

f

Switch (M)

g

±55 mA (M)

Figure C2

h

0 to 24 mA (S)

i

11 RTDs (M/S)

Figure C3 (2, 3, 4-wire)

j

12 TCs (M/S)

Figure C4

k

±300 Vac: AC probe

Figure C5 (Part: IO620-AC)

A1.2

DPI 620: Channel 2 (CH2)

l

±30 V (M)

m

±2000 mV (M)

n

±55 mA (M)

Figure D1

o

0 to 24 mA (S)

p

24 V loop (P)

q

Switch (M)

A1.3

DPI 620 + MC 620 + PM 620

Pressure* (M)

Figure E1 

Gauge: 25 mbar to 200 bar (0.36 to 3000 psi) 

 

Absolute: 350 mbar to 1000 bar (5 to 15000 psi) 

Note: 

Maximum pneumatic pressure: 500 bar (7250 psi) 

* Caution: To prevent damage to the PM 620 module, only 

use it within the specified pressure limit on the label.

© 2008 General Electric Company. All rights reserved.

Trademarks

All product names are trademarks of their respective companies.

Summary of Contents for Druck DPI 620

Page 1: ...S Figure C4 k 300 Vac AC probe Figure C5 Part IO620 AC A1 2 DPI 620 Channel 2 CH2 l 30 V M m 2000 mV M n 55 mA M Figure D1 o 0 to 24 mA S p 24 V loop P q Switch M A1 3 DPI 620 MC 620 PM 620 Pressure...

Page 2: ...12 f c e 11 b a d b 2 a 1 a 2 2 1 1 3 3 5 4 a b 2 4 3 1 C1 DPI 620 CH1 C2 DPI 620 CH1 C3 DPI 620 CH1 C4 DPI 620 CH1 C5 DPI 620 CH1 E1 DPI 620 MC 620 PM 620 C 4 D1 DPI 620 CH2 A1 1 a b c d e f V mV Hz...

Page 3: ...is dangerous to ignore the specified warnings Start operations S1 to S4 S1 Install the battery Refer to Section 5 S2 Power on off sequence S3 Example change of function Voltage to Current ON First dis...

Page 4: ...ximise minimise set voltage Menu sequence Task Settings CH1 CH2 Channel Settings Function Units Utility Caption Select Function None Current Voltage A channel can only have one function at a time TAP...

Page 5: ...ic or hydraulic pressures you can have up to two interchangeable pressure transducers at a time Pressure modules PM 620 Optional item These modules attach to the pressure module carrier MC 620 or to a...

Page 6: ...tween the terminals and the ground earth To prevent electrical shocks use only the GE specified AC probe Part IO620 AC to measure AC voltages maximum 300 Vac This instrument uses a Lithium Polymer Li...

Page 7: ...figures on the front cover A2 B1 4 1 Key to figure A2 DPI 620 calibrator Complies with European Union directives Warning refer to the manual Read the manual USB ports Type A Mini type B connector Grou...

Page 8: ...he display is set by the number of task selections and external modules you are working with maximum 6 12 Tap this button to set up the Task set up the instrument Configure and to access Help Refer to...

Page 9: ...onnections and then tighten to the applicable torque Maximum torque 1 8 NPT 35 Nm 26 lbf ft G1 8 25 Nm 18 4 lbf ft A3 Step Procedure 1 When the power is off loosen the five screws a and remove the cov...

Page 10: ...ay with touch screen Operating temperature 10 to 50 C 14 to 122 F Storage temperature 20 to 70 C 4 to 158 F Ingress Protection IP65 DPI 620 calibrator only Humidity 0 to 90 relative humidity RH non co...

Page 11: ...Customer service Visit our web site www gesensing com...

Reviews: