Appendix A
Data Conversion
482
Difference
New models:
A numeric value of up to 10 digits can be input for a %
value.
Conventional models:
A numeric value of up to 8 digits can be input for a %
value.
Conversion result, error message and corrective action
Status before
Conversion
Status after
Conversion
Error Message
Corrective Action
With a new model,
a graph for which a
value greater than
100000000 or
smaller than
–10000000 is set
for a % value is reg-
istered.
With a conventional
model, if a % value
is outside the allow-
able range, it is re-
placed as shown
below: for a 100%
value, the existing
value is corrected to
100, for a 0% value,
it is corrected to 0,
and for a –100%
value, it is corrected
to –100.
[W]
[Object Name] – %
value is out of limit.
Default values re-
stored for 100%,
0% and –100%.
Correct the screen data
or the program at the
host so that a constant
of up to 8 digits suffices.
(Refer to 6-9 Graph.)
Correction related to the label component of standard lamp and touch switch
In the conversion of the data between a NT31/631-V2 or later model and a
NT31/631-V1 or earlier model, conversion is executed in the manner shown be-
low due to differences in the label data of standard lamp and touch switch.
Difference
V2 or later models:
On label and Off label can be different.
Other models:
On label and Off label should be same.
Conversion result, error message and corrective action
Status before
Conversion
Status after
Conversion
Error Message
Corrective Action
With a V2 or later
model, a standard
lamp/touch switch
label type is set to
Static’ and On/Off
label descriptions
are different.
With a V2 or earlier
model, standard
lamp/touch switch
label type is set to
Static’ and On label
description will be
set to that of Off la-
bel.
[W]
Label Type-On Off
Static is not sup-
ported. Label will
set to Off descrip-
tion.
None
With a V2 or later
model, set Standard
Lamp/Touch Switch
label to “Label<\n>
in <\n> multiple
<\n> lines”.
With a V2 or earlier
model, standard
lamp/touch switch
label set to “Label”
(Default).
[W]
Label Type-Static
not supported. La-
bel will set to de-
fault.
None
From a 31/631-V2
model application
copy Touch Switch/
Standard Lamp with
Label Type set to
Numeral Display or
String Display and
paste in an applica-
tion for a model ear-
lier than V2.
Label properties are
set to default.
[W] Label Type-Nu-
meral Display not
supported. Label
will set to default.
(Or)
[W] Label Type-
String Display not
supported. Label
will set to default.
None
Correction related to ‘switch screen’ screen numbers
In the conversion of the data between a V2 or later model and a V1 or earlier mod-
el, conversion is executed in the manner shown below due to differences in the
new device monitor screens available in V2 or later models.