9-3
Section
Creating the Sample Data
381
(1) Select [Screen] (menu bar)
→
[New].
(2) At the screen selection dialog box, set “Standard Screen.”
(3) At the new standard screen dialog box, set 3 for the screen No.
Setting the screen properties
(1) Select [Screen] (menu bar)
→
[Properties].
(2) Set the screen properties as shown below for screen No. 3.
Attributes
Screen No.
3
History
Title
Set Screen
Comment
Set Screen
Buzzer
Load Local 1 (Keyboard)
System Keypad
Color
Background
Black
Grid
Grid Size
Custom
Horizontal Spacing:
5
Vertical Spacing:
5
Display Grid
Snap to Grid
Creating the screen title ([Set Screen])
Copying the screen title from screen No. 1 (Menu Screen)
(1) Copy the “Menu Screen” character string and its frame (rectangle) on
screen No. 1 and paste them onto screen No. 3.
(2) Adjust the display position of the pasted character string and frame to the
desired position.
Modifying to [Set Screen]
(3) Double click the “Menu Screen” character string and modify the properties
as shown below. Note that other properties must be left unchanged.
Description
Set Screen
(4) Adjust the size of the frame (rectangle).
Creating the data input field ([Numeral Input 1])