6-4
Section
Data Input
174
Display Type (Only Decimal can be set for NT11S/NT11.)
*1
Decimal:
Specify this item to display the input numeric value in decimal.
Hexadecimal:
Specify this item to display the input numeric value in hexade-
cimal.
Format
*2
Integer:
Specify the number of digits of the integer part of the input
data.
Decimal:
Specify the number of digits of the decimal fraction part of the
input data.
Limit (Setting is not possible for NT11S/NT11.)
*1
Maximum:
Specify the upper limit of the input data.
*3
Minimum:
Specify the lower limit of the input data.
*3
Zero Suppression:
*1
Specify whether or not leading zeros are suppressed to
display the input data.
Display Sign:
*1
Specify if a sign is displayed for a negative value.
Focus Frame:
Specify whether or not the frame that indicates the data in-
put objective is displayed. (Setting is not possible for
NT11S/NT11, NT20S and NT600S.)
Focus Attribute:
Specify how the input data is displayed before it is con-
firmed. Standard, Inverse, Flash, Inverse Flash
*1: Setting is not possible when a numeral input is used as a temporary input
field for the NT21, NT31, NT31C, NT631, and NT631C.
*2: When a numeral input is used as a temporary input field for the NT21, NT31,
NT31C, NT631, and NT631C, only No. of digits (sign digit + integer digit +
decimal point + decimal digit) can be specified, since the digits such as deci-
mal digits are determined by the numeral input field on a base screen.
*3: An input method for a negative value in decimal differs between the following
types of PT.
With NT20, NT20S, NT30, NT30C, NT600S, NT620S, NT620C, and
NT625C:
Input F to indicate a negative value in the most significant digit.
(e.g., F0000008)
With NT21, NT31, NT31C, NT631, and NT631C:
Input – (negative sign) in the most significant digit.
(e.g., –8)
When setting values with decimal fractions, such as 0.1234, 1.234, or 123.4 for
upper limits or lower limits, input only the 4-digit integer.
Interlock
Refer to 6-1-12 Interlock.
Guidance
When a numeral input element is specified, a dialog box is displayed to set
whether the cursor moving touch switch is automatically created or not.