7
© 2012 OKI DATA CORPORATION All rights reserved
ES9160 MFP / ES9170 MFP
PREVENTIVE MAINTENANCE (PM)
7 - 17
7.7
Preventive Maintenance Checklist
The following is the check items of each unit at preventive maintenance.
Symbols/Values used in the checklist
Notes:
•
Perform cleaning and lubricating in the following timing. Lubricate the replacement parts
according to the replacement cycle.
- ES9160 MFP: every 125,000 sheets
- ES9170 MFP: every 150,000 sheets
•
Values under “Replacement” indicate the replacement cycle for the ES9160 MFP or ES9170
MFP.
•
The replacement cycle of the parts in the feeding section equals to the number of sheets fed
from each paper source.
•
Be careful not to put oil on the rollers, belts and belt pulleys when lubricating.
Cleaning
Lubrication/Coating
Replacement
Operation check
A: Clean with alcohol
B: Clean with soft pad,
cloth or vacuum
cleaner
L: Launa
40
SI: Silicon oil
W1: White grease (Molykote EM-
30L)
W2: White grease (Molykote HP-
300)
AV: Alvania No.2
FL: Floil (GE-334C)
CG: Conductive grease (KS-660)
C: Coating material
(SANKOL CFD-409M)
Value: Replacement
cycle
R: Replace if
deformed or
damaged
After cleaning or
replacement, confirm
there is no problem.
Summary of Contents for ES9160
Page 12: ......
Page 24: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved FEATURES 1 2...
Page 308: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved SELF DIAGNOSIS MODES 5 56...
Page 832: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved REMOTE SERVICE 10 38...
Page 920: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 12...
Page 1086: ......
Page 1087: ......