6
© 2012 OKI DATA CORPORATION All rights reserved
ES9160 MFP / ES9170 MFP
SETTING / ADJUSTMENT
6 - 101
[ 2 ] Reseting procedure
The setting values which are set in
P. 6-95 "[ 1 ] Adjusting procedure"can be reset with the following
steps.
(1)
Turn OFF the power of the equipment.
(2)
Remove 1 screw and take off the board access cover.
(3)
Set the SW1 on the Finisher control board as shown in the figures below.
Fig.6-111
(4)
Turn ON the power of the equipment while pressing the [0] button and the [8] button
simultaneously.
(5)
Press [Button1] 11 times, press [Button2] once, press [Button1] 11 times , and then press
[Button2] once.
(6)
Press [Button1] and [Button2] simultaneously.
(7)
Turn OFF the power of the equipment.
(8)
Turn OFF all bits of SW1 on the Finisher control board as shown below.
Fig.6-112
(9)
Install the board access cover with 1 screw.