![Oki ES9160 Maintenance Manual Download Page 642](http://html1.mh-extra.com/html/oki/es9160/es9160_maintenance-manual_4506366642.webp)
ES9160 MFP / ES9170 MFP
© 2012 OKI DATA CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 162
[CC22] Saddle stich stapler home position detection error
MJ-1033
Probable cause
Checking and measures
Saddle stitch 3rd transport roller
drive motor (M10) abnormality
Check if the electrical continuity of the coil is normal. If
electricity is not conducted, replace the motor.
Saddle stitch 3rd transport roller
home position sensor (S23)
abnormality
Measure the voltage on TP67 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower
when not shielded and within the range of 3.3V
±
5% when
shielded. If the voltage does not fall within the range mentioned,
replace the sensor.
Faulty cables and connectors
Check if the electrical continuity between the connector
terminals is normal. If electricity is not conducted, replace the
connectors. (Finisher control PC board (FIN): CN6, CN16)
Finisher control PC board (FIN)
abnormality
If the error still occurs after replacing the motor, sensor and
connectors, exchange the finisher control PC board (FIN).
Error
Timing of detection
Saddle stitch stapler motor
Saddle stitch staple unit clinching
home position sensor
The turning OFF of the saddle stitch staple unit clinching home
position sensor (S32) is not detected in the specified time when
saddle stitch stapling is performed.
The turning ON of the saddle stitch staple unit clinching home
position sensor (S32) is not detected in the specified time after
the turning OFF of this sensor had been detected when saddle
stitch stapling is performed, and also the turning ON of this
sensor is not detected in a reverse rotation after the saddle
stitch stapler is stopped.
Probable cause
Checking and measures
Saddle stitch stapler motor (M14)
abnormality
Check if the electrical continuity of the coil is normal. If
electricity is not conducted, replace the saddle stitch staple unit.
Saddle stitch staple unit clinching
home position sensor (S32)
abnormality
Measure the voltage on pin CN17.5 on the finisher control PC
board (FIN). Then check that the measured voltage is 1V or
lower when the sensor is ON and within the range of 5V
±
5%
when OFF. If the voltage does not fall within the range
mentioned, replace the saddle stitch staple unit.
Faulty cables and connectors
Check if the electrical continuity between the connector
terminals is normal. If electricity is not conducted, replace the
saddle stitch staple unit.
Finisher control PC board (FIN)
abnormality
If the error still occurs after replacing the saddle stitch staple
unit and the connectors, exchange the finisher control PC board
(FIN).
Saddle stitch staple empty sensor
(S33) abnormality
Measure the voltage on pin CN17.7 on the finisher control PC
board (FIN). Then check that the measured voltage is 1V or
lower when the sensor is ON and within the range of 5V
±
5%
when OFF. If the voltage does not fall within the range
mentioned, replace the saddle stitch staple unit.
Faulty cables and connectors
Check if the electrical continuity between the connector
terminals is normal. If electricity is not conducted, replace the
saddle stitch staple unit.
Finisher control PC board (FIN)
abnormality
If the error still occurs after replacing the saddle stitch staple
unit and the connector, exchange the finisher control PC board
(FIN).
Summary of Contents for ES9160
Page 12: ......
Page 24: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved FEATURES 1 2...
Page 308: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved SELF DIAGNOSIS MODES 5 56...
Page 832: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved REMOTE SERVICE 10 38...
Page 920: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 12...
Page 1086: ......
Page 1087: ......