![Oki ES9160 Maintenance Manual Download Page 632](http://html1.mh-extra.com/html/oki/es9160/es9160_maintenance-manual_4506366632.webp)
ES9160 MFP / ES9170 MFP
© 2012 OKI DATA CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 152
[CB51] Staple unit sliding motor (M11) abnormality
MJ-1033
[CB60] Stapler unit shift motor abnormality
MJ-1101
Error
Timing of detection
Staple unit slidingEdge staple unit
sliding home position sensor motor
The turning OFF of the edge staple unit sliding home position sensor
(S14) is not detected in the specified time when the edge staple unit is
moved from a point where this sensor is turned ON to one point where
this sensor is turned OFF.
The turning ON of the edge staple unit sliding home position sensor
(S14) is not detected in the specified time when the edge staple unit is
moved from a point where this sensor is turned OFF to one point
where this sensor is turned ON.
Probable cause
Checking and measures
Staple unit sliding motor (M11)
abnormality
Check if the electrical continuity of the coil is normal. If electricity is not
conducted, replace the staple unit.
Edge staple unit sliding home
position sensor (S14) abnormality
Measure the voltage on pin CN7.6 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when not
shielded and within the range of 3.3V
±
5% when shielded. If the voltage does not fall within the range
mentioned, replace the sensor.
Saddle stitch staple unit sliding home
position sensor (S22) abnormality
Measure the voltage on pin CN7.10 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when not
shielded and within the range of 3.3V
±
5% when shielded. If the voltage does not fall within the range
mentioned, replace the sensor.
Edge staple unit improper clinching
prevention sensor (S25)
abnormality
Measure the voltage on pin CN10.11 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when not
shielded and within the range of 3.3V
±
5% when shielded. If the voltage does not fall within the range
mentioned, replace the sensor.
Faulty cables and connectors
Check if the electrical continuity between the connector terminals is
normal. If electricity is not conducted, replace the connectors. (Finisher
control PC board (FIN): CN7, CN10, CN17)
Finisher control PC board (FIN)
abnormality
If the error still occurs after replacing the staple unit, sensors and
connectors, exchange the finisher control PC board (FIN).
Classification
Contents
Finisher related service call
Stapler shift motor abnormality: Stapler shift motor is not
rotating or staple unit is not moving normally.
Check Item
Measure
Stapler
If there is mechanical problem when the stapler is moved, fix
the mechanism.
Stapler unit shift motor (M4)
Check the connectors and harnesses between the stapler unit
shift motor (M4) and the finisher control PC board (CN5).
Replacement part
Measure
Stapler unit shift motor (M4)
Finisher controller PC board
Summary of Contents for ES9160
Page 12: ......
Page 24: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved FEATURES 1 2...
Page 308: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved SELF DIAGNOSIS MODES 5 56...
Page 832: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved REMOTE SERVICE 10 38...
Page 920: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 12...
Page 1086: ......