05/08
Mode
Element
Sub
element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce
dure
Servic
e UI
08
Setting
mode
Process
Fuser
2075
Pre-running operation
cycle in ready status
and energy saving
mode (Times of heat
source ON)
Refer to
content
s
0~6
M
0: Not controlled 1: 180 times 2: 360 times 3: 540
times 4: 720 times 5: 900 times 6: 1080 times
<Default value>
3
1
08
Setting
mode
Process
Fuser
2100
Temperature setting
of warming-up(Center
thermistor)
Refer to
content
s
0~14
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5:
165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10:
190°C 11: 195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
8
1
08
Setting
mode
Process
Fuser
2101
Temperature setting
of warming-up(Side
thermistor)
Refer to
content
s
0~14
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5:
165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10:
190°C 11: 195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
8
1
08
Setting
mode
Process
Fuser
2111
Pre-running time
(Normal temperature)
3
0~18
M
0: Disabled 1: 1 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5
sec. 6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 sec.
11: 15 sec. 12: 20 sec. 13: 25 sec. 14: 30 sec. 15: 40
sec. 16: 50 sec. 17: 60 sec.
18: 150 sec.
1
08
Setting
mode
Process
Fuser
2120
Fuser roller
temperature in ready
status(Side
thermistor)
Refer to
content
s
0~12
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5: 165°C
6: 170°C 7: 175°C 8: 180°C 9: 185°C 10: 190°C 11:
195°C 12: 200°C
<Default value>
10
1
08
Setting
mode
Process
Fuser
Temperature drop
setting in ready status
(Side thermistor)
2121
0
The first drop
Refer to
content
s
0~10
M
This code is valid only when "20" is set to 08-2135.
Setting value x -5°C: from 0°C to -50°C
<Default value>
0
4
08
Setting
mode
Process
Fuser
Temperature drop
setting in ready status
(Side thermistor)
2121
1
The second drop
Refer to
content
s
0~10
M
This code is valid only when "20" is set to 08-2135.
Setting value x -5°C: from 0°C to -50°C
<Default value>
0
4
08
Setting
mode
Process
Fuser
Temperature drop
setting in ready status
(Side thermistor)
2121
2
The third drop
Refer to
content
s
0~10
M
This code is valid only when "20" is set to 08-2135.
Setting value x -5°C: from 0°C to -50°C
<Default value>
0
4
08
Setting
mode
Process
Fuser
Temperature drop
setting in ready status
(Side thermistor)
2121
3
The fourth drop
Refer to
content
s
0~10
M
This code is valid only when "20" is set to 08-2135.
Setting value x -5°C: from 0°C to -50°C
<Default value>
0
4
3
Summary of Contents for ES9160
Page 12: ......
Page 24: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved FEATURES 1 2...
Page 308: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved SELF DIAGNOSIS MODES 5 56...
Page 832: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved REMOTE SERVICE 10 38...
Page 920: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 12...
Page 1086: ......
Page 1087: ......