ERROR CODE AND TROUBLESHOOTING
8 - 68
[E480] Bridge unit opened during printing
Classification
Error content
Cover open jam
Bridge unit open jam
Proce
dure
Check item
Result
Measure
Next
Step
1
Is the bridge unit open?
Yes
Remove the paper if there is any, then close
the unit.
No
2
2
Is the bridge unit opening/
closing switch working?
(Perform the input check
in the test mode: 03-
[FAX]ON/[4]/[E]
Yes
3
No
•
Check if the connector of the bridge unit
opening/closing switch is disconnected.
•
Check if the connector CN302 / CN400 on
the LGC board is disconnected.
•
Check if the connector pins are
disconnected and the harnesses are open
circuited.
•
Check if the conductor pattern on the LGC
board is short circuited or open circuited.
•
Replace the bridge unit opening/closing
switch.
•
Replace the LGC board.
3
Replacing board
•
Replace the LGC board.
Parts to be replaced
Remark
The bridge unit opening/closing
switch
LGC board
Summary of Contents for ES9160
Page 12: ......
Page 24: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved FEATURES 1 2...
Page 308: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved SELF DIAGNOSIS MODES 5 56...
Page 832: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved REMOTE SERVICE 10 38...
Page 920: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 12...
Page 1086: ......
Page 1087: ......