05/08
Mode
Element
Sub
element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce
dure
Servic
e UI
08
Setting
mode
Process
Fuser
2140
Fuser roller
temperature during
printing(Side
thermistor/Plain
paper)
Refer to
content
s
0~14
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5: 165°C
6: 170°C 7: 175°C 8: 180°C 9: 185°C 10: 190°C 11:
195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
10
1
08
Setting
mode
Process
Fuser
2141
Fuser roller
temperature during
printing(Side
thermistor/Thick
paper 1)
Refer to
content
s
0~14
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5: 165°C
6: 170°C 7: 175°C 8: 180°C 9: 185°C 10: 190°C 11:
195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
10
1
08
Setting
mode
Process
Fuser
2142
Fuser roller
temperature during
printing(Side
thermistor/Thick
paper 2)
Refer to
content
s
0~14
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5: 165°C
6: 170°C 7: 175°C 8: 180°C 9: 185°C 10: 190°C 11:
195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
10
1
08
Setting
mode
Process
Fuser
2143
Fuser roller
temperature during
printing(Side
thermistor/OHP film)
Refer to
content
s
0~14
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5: 165°C
6: 170°C 7: 175°C 8: 180°C 9: 185°C 10: 190°C 11:
195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
10
1
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing(Center
thermistor)
2190
0
The first drop
Refer to
content
s
0~10
M
Setting value x -5°C: from 0°C to -50°C
This code is valid only when "20" is set to 08-2214-0.
<Default value>
0
4
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing(Center
thermistor)
2190
1
The second drop
2
0~10
M
Setting value x -5°C: from 0°C to -50°C
This code is valid only when "20" is set to 08-2214-0.
4
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing(Center
thermistor)
2190
2
The third drop
Refer to
content
s
0~10
M
Setting value x -5°C: from 0°C to -50°C
This code is valid only when "20" is set to 08-2214-0.
<Default value>
3
4
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing(Center
thermistor)
2190
3
The fourth drop
3
0~10
M
Setting value x -5°C: from 0°C to -50°C
This code is valid only when "20" is set to 08-2214-0.
4
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing(Side
thermistor)
2191
0
The first drop
Refer to
content
s
0~10
M
Setting value x -5°C: from 0°C to -50°C
This code is valid only when "20" is set to 08-2214-0.
<Default value>
4
4
5
Summary of Contents for ES9160
Page 12: ......
Page 24: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved FEATURES 1 2...
Page 308: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved SELF DIAGNOSIS MODES 5 56...
Page 832: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved REMOTE SERVICE 10 38...
Page 920: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 12...
Page 1086: ......