![Oki ES9160 Maintenance Manual Download Page 544](http://html1.mh-extra.com/html/oki/es9160/es9160_maintenance-manual_4506366544.webp)
ES9160 MFP / ES9170 MFP
© 2012 OKI DATA CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 64
[E420] PFP side cover opened during printing
Classification
Error content
Cover open jam
PFP side cover open jam
Proce
dure
Check item
Result
Measure
Next
Step
1
Is the PFP side cover
open?
Yes
Remove the paper if there is any, then close
the cover.
No
2
2
Is the PFP side cover
opening/closing switch
working?
(Perform the input check
in the test mode: 03-
[FAX]OFF/[2]/[A])
Yes
3
No
•
Check if the connector of the PFP side
cover opening/closing switch is
disconnected.
•
Check if either of the connectors CN241 or
CN243 on the PFP board is disconnected.
•
Check if the connector CN318 on the LGC
board is disconnected.
•
Check if the connector pins are
disconnected and the harnesses are open
circuited.
•
Check if the conductor patterns on the PFP
board and LGC board are short circuited or
open circuited.
•
Replace the PFP side cover opening/
closing switch.
•
Replace the PFP board.
•
Replace the LGC board.
3
Replacing board
•
Replace the PFP board.
•
Replace the LGC board.
Parts to be replaced
Remark
PFP side cover opening/closing
switch
PFP board
LGC board
Summary of Contents for ES9160
Page 12: ......
Page 24: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved FEATURES 1 2...
Page 308: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved SELF DIAGNOSIS MODES 5 56...
Page 832: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved REMOTE SERVICE 10 38...
Page 920: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 12...
Page 1086: ......
Page 1087: ......