FIRMWARE UPDATING
11 - 73
11.7
When Firmware Updating Fails
When the equipment was shut down during firmware updating or it could not be started after updating
for some reason, perform firmware updating again following the procedure below.
11.7.1
Procedure
(1)
Update “System ROM“ of the system control PC board (SYS board) using the download jig
(PWA-DWNLD-350-JIG1).
Updating with the USB media becomes possible only after the “System ROM” (OS data) has
been updated.
See the updating procedure below for details.
P. 11-30 "11.4 Firmware Updating with PWA-DWNLD-350-JIG1"
(2)
Update “Master Data”, “Engine ROM” , “Scanner ROM” and “RADF ROM” using the USB media.
See the updating procedure below for details.
P. 11-7 "11.2 Firmware Updating with USB Media"
(3)
When the update with the USB media for “Scanner ROM” and “RADF ROM” failed, update these
ROMs using the respective download jigs in the table below.
Important:
If the equipment cannot be started even when the above update has been performed, check that
there is no damage to the “SYS board”, “LGC board”, “SLG board” or “DLG board”. Replace
them if necessary.
Firmware
Storage location
Download jig
Scanner ROM
Scanning section control PC board
(SLG board)
K-PWA-DLM-320
RADF ROM
DLG board
K-PWA-DLM-320
Summary of Contents for ES9160
Page 12: ......
Page 24: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved FEATURES 1 2...
Page 308: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved SELF DIAGNOSIS MODES 5 56...
Page 832: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved REMOTE SERVICE 10 38...
Page 920: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 12...
Page 1086: ......
Page 1087: ......