6.12 Adjustment of Dogleg
Dogleg is the name given to an image which is deformed approx. 48 mm of the trailing edge of the
output paper.
Since adjustment has usually been performed when the equipment was manufactured, dogleg image
should not occur. However, if the following dogleg image A or B does happen to occur, the following
adjustment must be performed. An original with a line parallel to the feeding direction is used for the
adjustment.
Fig.6-57
Fig.6-58
Fig.6-59
Normal Image
Feeding
Direction
Feeding
Direction
Dogleg Image A
Approx. 48 mm of
the trailing edge
Dogleg Image B
Feeding
Direction
Approx. 48 mm of
the trailing edge