05/08
Mode
Element
Sub
element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce
dure
Servic
e UI
08
Setting
mode
Process
Fuser
2214
0
Temperature drop
control setting during
printing(Temperature/
Time)
Refer to
content
s
0~20
M
0: None 1: Pattern 1 2: Pattern 2 3: Pattern 3 4: Pattern
4 5: Pattern 5 6: Pattern 6 7: Pattern 7 8: Pattern 8 9:
Pattern 9 10: Pattern 10 11: Pattern 11 12: Pattern 12
13: Pattern 13 14: Pattern 14 15: Pattern 15 16: Pattern
16 17: Pattern 17 18: Pattern 18 19: Pattern 19 20:
Manual adjustment
<Default value>
20
4
08
Setting
mode
Process
Fuser
2214
1
Temperature drop
control setting during
printing(Temperature/
Time)
Refer to
content
s
0~20
M
0: None 1: Pattern 1 2: Pattern 2 3: Pattern 3 4: Pattern
4 5: Pattern 5 6: Pattern 6 7: Pattern 7 8: Pattern 8 9:
Pattern 9 10: Pattern 10 11: Pattern 11 12: Pattern 12
13: Pattern 13 14: Pattern 14 15: Pattern 15 16: Pattern
16 17: Pattern 17 18: Pattern 18 19: Pattern 19 20:
Manual adjustment
<Default value>
20
4
08
Setting
mode
Process
Fuser
Energy Saving Mode
Fuser roller
temperature
2250
Side thermistor
0
0~13
M
0: OFF 1: 40°C 2: 50°C 3: 60°C 4: 70°C 5: 80°C
6: 90°C 7: 100°C 8: 110°C 9: 120°C 10: 130°C
11: 140°C 12: 150°C 13: 160°C
1
Yes
08
Setting
mode
Process
Fuser
2282
Pre-running time for
first
printing(Envelope)
10
0~15
M
0: Invalid 1: 1 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 sec. 11: 12
sec. 12: 14 sec. 13: 16 sec. 14: 18 sec. 15: 20 sec.
1
08
Setting
mode
Process
Developer
2827
Developer bias AC
control ON/OFF
1
0~2
M
0: ON 1: ON-OFF 2: OFF
1
08
Setting
mode
Process
Process
2835
Switching of recycled
toner saving control
0
0~1
M
0: Switched 1: Not switched
1
08
Setting
mode
Process
Process
2837
Correction by
temperature/humidity
0
0~3
M
Sets the correction by temperature/humidity.
0: All valid
1: All invalid
2: Valid only in autotoner sensor
3: All valid except transfer and separation
1
08
Setting
mode
Process
Process
2847
Life correction
switching of drum
reverse rotation
amount
Refer to
content
s
0~30
M
Set value x 4 msec. = Drum rotation time
0: No correction
1 to 30: Corrected (4 to 120 msec.: approx. 0.8 to
25mm)
<Default value>
2
1
11
Summary of Contents for ES9160
Page 12: ......
Page 24: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved FEATURES 1 2...
Page 308: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved SELF DIAGNOSIS MODES 5 56...
Page 832: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved REMOTE SERVICE 10 38...
Page 920: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 12...
Page 1086: ......
Page 1087: ......