05/08
Mode
Element
Sub
element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce
dure
Servic
e UI
08
Setting
mode
Process
Fuser
Temperature control
lower limit(Envelope)
2211
1
Side thermistor
Refer to
content
s
0~12
M
0: 130°C 1: 135°C 2: 140°C 3: 145°C 4: 150°C 5: 155°C
6: 160°C 7: 165°C 8: 170°C 9: 175°C 10: 180°C 11:
185°C 12: 120°C
<Default value>
7
4
08
Setting
mode
Process
Fuser
Temperature drop
switching time setting
during printing(Center
thermistor)
2212
0
The first drop
Refer to
content
s
0~200
M
Setting value x 5 sec.: from 0 to 1,000 sec. later
This code is valid only when "20" is set to 08-2214-0.
<Default value>
5
4
08
Setting
mode
Process
Fuser
Temperature drop
switching time setting
during printing(Center
thermistor)
2212
1
The second drop
Refer to
content
s
0~200
M
Setting value x 5 sec.: from 0 to 1,000 sec. later
This code is valid only when "20" is set to 08-2214-0.
<Default value>
18
4
08
Setting
mode
Process
Fuser
Temperature drop
switching time setting
during printing(Center
thermistor)
2212
2
The third drop
Refer to
content
s
0~200
M
Setting value x 5 sec.: from 0 to 1,000 sec. later
This code is valid only when "20" is set to 08-2214-0.
<Default value>
24
4
08
Setting
mode
Process
Fuser
Temperature drop
switching time setting
during printing(Center
thermistor)
2212
3
The fourth drop
75
0~200
M
Setting value x 5 sec.: from 0 to 1,000 sec. later
This code is valid only when "20" is set to 08-2214-0.
4
08
Setting
mode
Process
Fuser
Temperature drop
switching time setting
during printing(Side
thermistor)
2213
0
The first drop
Refer to
content
s
0~200
M
Setting value x 5 sec.: from 0 to 1,000 sec. later
This code is valid only when "20" is set to 08-2214-0.
<Default value>
5
4
08
Setting
mode
Process
Fuser
Temperature drop
switching time setting
during printing(Side
thermistor)
2213
1
The second drop
Refer to
content
s
0~200
M
Setting value x 5 sec.: from 0 to 1,000 sec. later
This code is valid only when "20" is set to 08-2214-0.
<Default value>
18
4
08
Setting
mode
Process
Fuser
Temperature drop
switching time setting
during printing(Side
thermistor)
2213
2
The third drop
Refer to
content
s
0~200
M
Setting value x 5 sec.: from 0 to 1,000 sec. later
This code is valid only when "20" is set to 08-2214-0.
<Default value>
24
4
08
Setting
mode
Process
Fuser
Temperature drop
switching time setting
during printing(Side
thermistor)
2213
3
The fourth drop
75
0~200
M
Setting value x 5 sec.: from 0 to 1,000 sec. later
This code is valid only when "20" is set to 08-2214-0.
4
10
Summary of Contents for ES9160
Page 12: ......
Page 24: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved FEATURES 1 2...
Page 308: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved SELF DIAGNOSIS MODES 5 56...
Page 832: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved REMOTE SERVICE 10 38...
Page 920: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 12...
Page 1086: ......
Page 1087: ......