615
Chapter 16
FCAN Controller
User’s Manual U16702EE3V2UD00
Figure 16-41:
CAN Module Time Stamp Register (CnTS) Format (2/2)
(b) Write
TSSEL
Time stamp capture event selection bit
0
The time capture event is SOF.
1
The time stamp capture event is the last bit of EOF.
TSEN
TSOUT operation setting bit
0
TSOUT toggle operation is disabled.
1
TSOUT toggle operation is enabled.
Set TSLOCK Clear TSLOCK
Setting of TSLOCK bit
0
1
TSLOCK bit is cleared to 0.
1
0
TSLOCK bit is set to 1.
Other than above
TSLOCK bit is not changed.
Set TSSEL
Clear TSSEL
Setting of TSSEL bit
0
1
TSSEL bit is cleared to 0.
1
0
TSSEL bit is set to 1.
Other than above
TSSEL bit is not changed.
Set TSEN
Clear TSEN
Setting of TSEN bit
0
1
TSEN bit is cleared to 0.
1
0
TSEN bit is set to 1.
Other than above
TSEN bit is not changed.