389
Chapter 11
A/D Converter
User’s Manual U16702EE3V2UD00
(4)
Continuous scan mode (Polling mode)
In this mode, A/D conversion is performed starting from ANI2 up to ANI5 specified by the
ADSCM0L register. The A/D conversion result is saved to the ADA0CRn register corresponding to
each analog input. A/D conversion starts from ANI0 upon trigger detection, an A/D conversion
interrupt (INTAD) is generated when conversion of the specified analog input ends, and A/D
conversion from ANI0 starts again.
Figure 11-13:
Example of Continuous Scan Mode Operation (ANI2 to ANI5) (1/2)
(a) Timing Example
Remark:
n = 2 to 5
Data 1
(ANI2)
Data 2
(ANI3)
Data 3
(ANI4)
Data 4
(ANI5)
Data 5
(ANI2)
Data 6
(ANI3)
Data 7
(ANI4)
Data 1
(ANI2)
Data 2
(ANI3)
Data 3
(ANI4)
Data 4
(ANI5)
Data 5
(ANI2)
Data 6
(ANI3)
ADA0CRn
INTAD
Conversion start
Set CE bit of ADSCM0H to 1
ANI5
ANI2
ANI3
ANI4
Data 1
Data 2
Data 3
Data 4
Data 6
Data 5
Data 7
A/D conversion