Prefix:
PLAT
ID:
0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
•
80010204-1d04xxxx : Numeric sensor [NumericSensorElementName] going low (lower critical)
has asserted. (Fan 4 Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d04xxxx or 0x800102041d04xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix:
PLAT
ID:
0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
•
80010701-1401xxxx : Numeric sensor [NumericSensorElementName] going high (upper
non-critical) has asserted. (CPU1 VR Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107011401xxxx or 0x800107011401xxxx
Severity
Warning
Serviceable
Yes
376
System x3500 M5 Installation and Service Guide
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......