806f0113-0302xxxx : A bus timeout has occurred on system [ComputerSystemElementName].
(CPU 2 PECI)
This message is for the use case when an implementation has detected a Bus Timeout.
May also be shown as 806f01130302xxxx or 0x806f01130302xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0224
User Response
1. (Trained technician only)Reseat the microprocessor, and then restart the server.
2. (Trained technician only)Replace microprocessor n. (n = microprocessor number)
•
806f0123-2101xxxx : Reboot of system [ComputerSystemElementName] initiated by
[WatchdogElementName]. (IPMI Watchdog)
This message is for the use case when an implementation has detected a Reboot by a Watchdog occurred.
May also be shown as 806f01232101xxxx or 0x806f01232101xxxx
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix:
PLAT
ID:
0370
User Response
502
System x3500 M5 Installation and Service Guide
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......