H
Installation tool
Microprocessor
Figure 71. Microprocessor installation tools
Read the safety information in “Safety” on page v and “Installation guidelines” on page 29.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
Attention:
When you handle static-sensitive devices, take precautions to avoid damage from static
electricity. For details about handling these devices, see “Handling static-sensitive devices” on page 31.
To replace a microprocessor and heat sink, complete the following steps:
Step 1.
Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 2.
Remove the left-side cover (see “Removing the left-side cover” on page 49).
Step 3.
Remove the air baffle (see “Removing the air baffle” on page 50).
Step 4.
If you are replacing microprocessor 1, remove the memory modules from DIMM connectors 6 and
7. If you are replacing microprocessor 2, remove the memory modules from DIMM connectors 18
and 19. See “Installing a DIMM” on page 79 for instructions.
Step 5.
Rotate the heat sink retention module release lever to the open position.
86
System x3500 M5 Installation and Service Guide
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......