4R = quad-rank
–
xff
is the device organization (bit width)
x4 = x4 organization (4 DQ lines per SDRAM)
x8 = x8 organization
x16 = x16 organization
–
v
is the SDRAM and support component supply voltage (VDD)
• Blank = 1.2 V specified
–
wwwww
is the DIMM bandwidth, in MBps
12800 = 12.80 GBps (DDR4-1600 SDRAMs, 8-byte primary data bus)
14900 = 14.93 GBps (DDR4-1866 SDRAMs, 8-byte primary data bus)
17000 = 17.00 GBps (DDR4-2133 SDRAMs, 8-byte primary data bus)
–
m
is the DIMM type
L = Load Reduction DIMM (LRDIMM)
R = Registered DIMM (RDIMM)
–
aa
is the CAS latency, in clocks at maximum operating frequency
–
bb
is the JEDEC SPD Revision Encoding and Additions level
–
cc
is the reference design file for the design of the DIMM
–
d
is the revision number of the reference design of the DIMM
Note:
To determine the type of a DIMM, see the label on the DIMM. The information on the label is in
the format xxxxx nRxxx PC4v-xxxxxx-xx-xx-xxx. The numeral in the sixth numerical position indicates
whether the DIMM is single-rank (n=1), dual-rank (n=2), or quad-rank (n=4).
• The following rules apply to DDR4 RDIMM speed as it relates to the number of RDIMMs in a channel:
– When you install 1 RDIMM per channel, the memory runs at 2133 MHz
– When you install 2 RDIMMs per channel, the memory runs at 1866 MHz
– When you install 3 RDIMMs per channel, the memory runs at 1600 MHz
– All channels in a server run at the fastest common frequency
– Do not install registered and load reduction DIMMs in the same server
• The following rules apply to DDR4 RDIMM speed as it relates to the number of LRDIMMs in a channel:
– When you install 1 LRDIMM per channel, the memory runs at 2133MHz
– When you install 2 LRDIMMs per channel, the memory runs at 2133 MHz
– When you install 3 LRDIMMs per channel, the memory runs at 1600 MHz
• The maximum memory speed is determined by the combination of the microprocessor, DIMM speed,
DIMM type, Operating Modes in UEFI settings, and the number of DIMMs installed in each channel.
• The server supports a maximum of 24 single-rank, dual-rank RDIMMs or 24 quad-rank LRIMMs.
• It is recommended to install DIMMs with the same rank in each channel.
• The following table shows an example of the maximum amount of memory that you can install using
ranked DIMMs:
74
System x3500 M5 Installation and Service Guide
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......