Step 1.
Is the server part of a cluster?
•
No:
Go to step 2.
•
Yes:
Shut down all failing servers that are related to the cluster. Go to step 2.
Step 2.
Complete the following steps:
a.
Check the power supply LEDs (see “Power-supply LEDs” on page 137).
b.
Turn off the server and all external devices.
c.
Check all internal and external devices for compatibility at http://www.lenovo.com/
serverproven/.
d.
Check all cables and power cords.
e.
Set all display controls to the middle positions.
f.
Turn on all external devices.
g.
Turn on the server. If the server does not start, see “Troubleshooting by symptom” on page 145.
h.
Check the system-error LED on the operator information panel. If it is lit, check the light path
diagnostics LEDs (see “Light path diagnostics” on page 131).
i.
Check for the following results:
• Successful completion of POST (see “POST” on page 141 for more information).
• Successful completion of startup, which is indicated by a readable display of the
operating-system desktop.
Step 3.
Is there a readable image on the monitor screen?
•
No:
Find the failure symptom in “Troubleshooting by symptom” on page 145; if necessary, see
“Solving undetermined problems” on page 158.
•
Yes:
Run DSA (see “Running DSA Preboot diagnostic programs” on page 143).
– If DSA reports an error, follow the instructions in Appendix C “DSA diagnostic test results”
– If DSA does not report an error but you still suspect a problem, see “Solving undetermined
Diagnostic tools
The following tools are available to help you diagnose and solve hardware-related problems.
•
Light path diagnostics
Use light path diagnostics to diagnose system errors quickly. See “Light path diagnostics” on page 131
for more information.
•
Event logs
The event logs list the error codes and messages that are generated when an error is detected for the
subsystems IMM2.1, POST, DSA, and the server baseboard management controller. See “Event logs” on
page 139 for more information.
•
Integrated Management Module II (IMM2)
The Integrated Management Module II (IMM2) combines service processor functions, video controller,
and remote presence and blue-screen capture features in a single chip. The IMM2.1 provides advanced
service-processor control, monitoring, and alerting function. If an environmental condition exceeds a
threshold or if a system component fails, the IMM2.1 lights LEDs to help you diagnose the problem,
records the error in the IMM2.1 event log, and alerts you to the problem. Optionally, the IMM2.1 also
provides a virtual presence capability for remote server management capabilities. The IMM2.1 provides
remote server management through the following industry-standard interfaces:
129
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......