Step 1.
Unlock the left-side cover.
Note:
You must unlock the left-side cover to open or remove the bezel. When you lock the left-side
cover, it locks both the cover and the bezel.
Step 2.
Open the bezel (see “Opening the bezel door” on page 47).
Step 3.
Remove the filler panel, if one is present.
Step 4.
Touch the static-protective package that contains the disk drive to any unpainted metal surface on
the server; then, remove the disk drive from the package and place it on a static-protective surface.
Step 5.
Make sure that the drive tray handle is in the open position.
Step 6.
Align the drive assembly with the guide rail in the bay; then, carefully slide the drive assembly into
the drive bay until the drive snaps into place.
0
000
00
000
00
00
0
000000000
0
0
1
2
Handle
Latch
3.5-inch hot-swap
hard disk drive
3.5-inch filler panel
Figure 60. Hot-swap hard disk drive installation
Step 7.
Rotate the drive tray handle to the closed position.
Step 8.
Check the hard disk drive status indicator to make sure that the hard disk drive is operating
correctly. After you replace a failed hard disk drive, the green activity LED flashes as the disk spins
up. The yellow LED turns off after approximately 1 minute. If the new drive starts to rebuild, the
yellow LED flashes slowly, and the green activity LED remains lit during the rebuild process. If the
yellow LED remains lit, see the “Hard disk drive problems” on page 147 for more information.
Note:
You might have to reconfigure the disk arrays after you install hard disk drives. See the
RAID documentation on the website at http://www.lenovo.com/support for information about
RAID adapters.
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation”
on page 97.
71
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......