3. Check Lenovo support site for any applicable service bulletin or UEFI or adapter firmware
update that applies to this error. NOTE: It may be necessary to configure slot to Gen1 or to use
special utility software so that adapter firmware can be upgraded. Gen1/Gen2 settings can be
configured via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3
Speed Selection, or the ToolsCenter Suite CLI Utility.
4.
Replace the adapter.
•
I.3808004 The IMM System Event log (SEL) is full. IPMI System Event Log is Full
Explanation:
Severity
Info
User Response
Complete the following steps:
1. Use the IMM Web Interface to clear the event log.
2. If IMM communication is unavailable, use F1 Setup to access System Event Logs Menu and
Choose Clear IMM System Event Log and Restart Server.
•
I.3818001 The firmware image capsule signature for the currently booted flash bank is invalid.
Current Bank CRTM Capsule Update Signature Invalid
Explanation:
Severity
Info
User Response
Complete the following steps:
1. Reboot the system. Will come up on backup UEFI image. Update the primary UEFI image.
2. If error does not persist no additional recovery action is required.
3. If error persists, or boot is unsuccessful, (Trained service technician only) Replace the system
board.
•
I.3818002 The firmware image capsule signature for the non-booted flash bank is invalid. Opposite
Bank CRTM Capsule Update Signature Invalid
Explanation:
Severity
Info
User Response
Complete the following steps:
1. Update the backup UEFI image.
2. If error does not persist no additional recovery action is required.
3. If error persists, or boot is unsuccessful, (Trained service technician only) Replace the system
board.
Appendix B. UEFI (POST) error codes
1021
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......