Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix:
PLAT
ID:
0810
User Response
1. Make sure that the connectors on fan n are not damaged.
2. Make sure that the fan n connectors on the system board are not damaged.
3. Make sure that the fans are correctly installed.
4.
Reseat the fans.
5. Replace the fans. (n = fan number)
•
800b050c-2581xxxx : Non-redundant:Insufficient Resources for [RedundancySetElementName]
has asserted. (Backup Memory)
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient
Resources.
May also be shown as 800b050c2581xxxx or 0x800b050c2581xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix:
PLAT
ID:
0810
User Response
1. Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the
failures.
420
System x3500 M5 Installation and Service Guide
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......