I.580A5 Mirror Fail-over complete. DIMM number [arg1] has failed over to to the mirrored copy.
DIMM Mirror Fail-over Detected
Explanation:
Severity
Info
User Response
Complete the following steps:
1. Check the system-event log for uncorrected DIMM failures and replace those DIMMs.
•
I.580A6 Memory spare copy has completed successfully. Spare Copy Complete
Explanation:
Severity
Info
User Response
Complete the following steps:
1. If you have added or removed DIMMs to the system, and no additional errors were detected,
then please ignore this message.
2. Check system event log for uncorrected DIMM failures and replace those DIMMs.
•
S.1100B CATERR(IERR) has asserted on processor [arg1]. Processor CATERR(IERR) has asserted
Explanation:
Severity
Error
User Response
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or UEFI firmware update that
applies to this Processor error.
2. (Trained service technician only) If there are multiple Processor’s, swap Processor’s to move
affected Processor to another Processor socket and retry. If problem follows the affected
Processor, or this is a single Processor system, replace the Processor.
3. (Trained Service technician only) Inspect Processor socket on each Processor removal and
replace system board first if damaged or mis-aligned pins are found. Replace the system board.
•
S.1100C An uncorrectable error has been detected on processor [arg1]. Uncorrectable processor
error detected
Explanation:
Severity
Error
User Response
Complete the following steps:
1024
System x3500 M5 Installation and Service Guide
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......