• See the documentation for the ServeRAID adapter for instructions for installing a hard disk drive.
• All hot-swap drives in the server must have the same throughput speed rating; using drives with different
speed ratings might cause all drives to operate at the speed of the slowest drive.
• You do not have to turn off the server to install hot-swap drives in the hot-swap drive bays. However, you
must turn off the server when you perform any steps that involve installing or removing cables.
Attention:
Static electricity that is released to internal server components when the server is powered-on
might cause the server to halt, which might result in the loss of data. To avoid this potential problem,
always use an electrostatic-discharge wrist strap or other grounding system when you work inside the
server with the power on.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 29.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
To install a 2.5-inch hot-swap hard disk drive, complete the following steps.
Step 1.
Unlock the left-side cover.
Note:
You must unlock the left-side cover to open or remove the bezel. When you lock the left-side
cover, it locks both the cover and the bezel.
Step 2.
Open the bezel (see “Removing the bezel” on page 184).
Step 3.
Remove the 2.5-inch filler panel, if one is present.
Step 4.
Touch the static-protective package that contains the disk drive to any unpainted metal surface
on the server; then, remove the disk drive from the package.
Step 5.
Make sure that the drive handle is opened by press the latch; then, install the hard disk drive
into the drive bay.
Step 6.
Rotate the drive handle until the drive is seated in the drive bay and the release latch clicks into
place.
Removing and replacing components
201
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......