![Lenovo System x3500 M5 Type 5464 Installation And Service Manual Download Page 242](http://html.mh-extra.com/html/lenovo/system-x3500-m5-type-5464/system-x3500-m5-type-5464_installation-and-service-manual_202661242.webp)
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
1
2
Fan
Fan-locking handle
Figure 146. Open the fan-locking handle
Step 4.
If you are instructed to return the hot-swap fan, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Installing a hot-swap fan
Use this information to install a hot-swap fan in the server.
Attention:
To avoid unexpected system shutdown, ensure that you lay the server on its side with the
cover facing up before you start.
Attention:
Static electricity that is released to internal server components when the server is powered-on
might cause the server to halt, which might result in the loss of data. To avoid this potential problem,
always use an electrostatic-discharge wrist strap or other grounding system when you work inside the
server with the power on.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 29.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
To install a hot-swap fan, complete the following steps.
Step 1.
Carefully turn the server on its side so that it is lying flat, with the cover facing up.
Step 2.
Touch the static-protective package that contains the hot-swap fan to any unpainted metal surface
on the server; then, remove the fan from the package.
Step 3.
Unlock and remove the left-side cover (see “Removing the left-side cover” on page 182).
Step 4.
Open the fan-locking handle of the replacement fan.
Step 5.
Insert the fan into the socket and close the handle to the locked position.
226
System x3500 M5 Installation and Service Guide
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......