Step 1.
Carefully turn the server on its side so that it is lying flat, with the cover facing up.
Attention:
Do not allow the server to fall over.
Step 2.
Unlock and remove the left-side cover (see “Removing the left-side cover” on page 182).
Step 3.
Remove the air baffle (see “Removing the air baffle” on page 188).
Step 4.
Disconnect the fan cage power cable from the system board (see “Internal cable routing and
connectors” on page 33).
Step 5.
Rotate the fan cage release latch to the open position.
0
00
00
0
00
0
0
00
00
00
1
2
Fan cage assembly
Figure 180. Fan cage removal
Step 6.
Grasp the fan cage assembly and lift it out of the server.
If you are instructed to return the server component or optional device, follow all packaging instructions,
and use any packaging materials for shipping that are supplied to you.
Installing the fan cage assembly
Use this information to install the fan cage assembly from the server.
Attention:
Make sure that all wires and cables inside the server are routed correctly before you install
the fan cage assembly. Wiring that is not properly routed might be damaged or might prevent the fan
cage assembly from seating properly in the server.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 29.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
To install the fan cage assembly, complete the following steps.
Step 1.
Carefully turn the server on its side so that it is lying flat, with the cover facing up.
262
System x3500 M5 Installation and Service Guide
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......