Step 5.
Connect one end of the battery/flash power module cable to the battery/flash power module
connector.
Step 6.
Route the remote battery/flash power module cable as shown in the following illustration.
ServeRAID adapter
Battery / flash power module
RAID adapter battery / flash
power module cable
Figure 141. Route the battery/flash power module
Attention:
Make sure that the cable is not connected and does not cover any connectors or
obstruct any components on the system board.
Step 7.
Install the battery/flash power module:
a.
Align the battery/flash power module cable to slot of the battery holder. Place the battery/flash
power module into the battery holder and make sure that the battery holder engages the
battery/flash power module securely.
1
2
Battery / flash power module
Battery holder
Retention clip
Figure 142. Align the battery/flash power module cable
Note:
The positioning of the remote battery/flash power module depends on the type of the
remote batteries/flash power module that you install.
b.
Lower and press down on the retention clip until it snaps in place to hold the battery/flash
power module firmly in place.
Step 8.
Reinstall the air baffle (see “Replacing the air baffle” on page 189).
222
System x3500 M5 Installation and Service Guide
Summary of Contents for System x3500 M5 Type 5464
Page 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Page 6: ...iv System x3500 M5 Installation and Service Guide ...
Page 16: ...xiv System x3500 M5 Installation and Service Guide ...
Page 140: ...124 System x3500 M5 Installation and Service Guide ...
Page 194: ...178 System x3500 M5 Installation and Service Guide ...
Page 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Page 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Page 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Page 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Page 1235: ......
Page 1236: ......